Artesyn System Management Interface Based on HPI-B (Centel Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Artesyn System Management Interface Based on HPI-B (Centel herunter. Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - (Centellis 2000 R3.0/4411)

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411)User’s GuideP/N: 6806800P20CJune 2014

Seite 2 - Contact Address

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)10List of Figures

Seite 3 - Contents

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)1009. If the update was successful, you may

Seite 4

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)10110.Activate the new, updated image by en

Seite 5

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)102

Seite 6

Appendix ASystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)103A Example ApplicationsA.1 OverviewThe HPI

Seite 7 - List of Tables

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)104A.3 List of Supported Example A

Seite 8

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)105 -V print ver

Seite 9

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)106 (Not applicab

Seite 10 - List of Figures

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)107 -x additionally

Seite 11 - About this Manual

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)108 -m mode set cooling m

Seite 12 - Conventions

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)109 -h display this he

Seite 13

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)11About this ManualOverview of ContentsThis manual is

Seite 14 - Summary of Changes

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)110Usage: hpifan [OPTION]...HPI ex

Seite 15 - 1.2 Standard Compliances

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)111# hpifrudeactivation#----------

Seite 16 - 1.3 Architecture

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)112# hpifruresetdiag#-------------

Seite 17 - 1.4 High Availability

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)113 -u calls saHpiFu

Seite 18

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)114Usage: hpiha [OPTION]...HPI exa

Seite 19 - 2.1 Overview

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)115 -y RESOURCE_ID power cycle r

Seite 20

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)116#------------------------------

Seite 21

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)117Send GetDeviceId command (Lun=0

Seite 22

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)118 -r RESOURCE_ID use resource

Seite 23

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)119 -h display this

Seite 24

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)About this Manual12About this ManualConventionsThe fol

Seite 25

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)120# hpiposttype#-----------------

Seite 26

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)121 -c commit power

Seite 27

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)122#------------------------------

Seite 28 - 2.3 Setting Up HPI Clients

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)123Add domain "Gandalf"

Seite 29 - 2.3.2 Configuring HPI Clients

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)124 -D walk recursi

Seite 30

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)125HPI example application to cont

Seite 31

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)126 -x display debug

Seite 32

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)127 DAEMON-HA-PROTO

Seite 33 - Procedure

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)128showevtlog showinv showrd

Seite 34

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)129event Enable or disable event d

Seite 35

About this ManualSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)13Courier + Bold Used to characterize

Seite 36

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)130rdr Show resource data record s

Seite 37 - Developing Applications

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)131showrdr Show resource data reco

Seite 38

Example ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)132

Seite 39

Appendix BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)133B Related DocumentationB.1 Artesyn Embedd

Seite 40

Related DocumentationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)134Service Availability Forumsafo

Seite 42 - 4.3 Backward Compatibility

Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, I

Seite 43 - 4.4.1 Overview

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)About this Manual14About this ManualSummary of Changes

Seite 44 - 4.4.2 Accessing HPI Domains

Chapter 1System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)15System Management Interface Overview1.1 Int

Seite 45

System Management Interface OverviewSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)161.3 Architecture

Seite 46

System Management Interface OverviewSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)171.3.1 HPI Librar

Seite 47

System Management Interface OverviewSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)18A supervisor whi

Seite 48

Chapter 2System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)19Software Installation and Configuration2.1

Seite 49

© Copyright 2014 Artesyn Embedded Technologies, Inc.All rights reserved.TrademarksArtesyn Embedded Technologies, Artesyn and the Artesyn Embedded Tec

Seite 50

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)20You can upgra

Seite 51 - 4.4.3.3 HPI Domain Events

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)21OPENHPI_DEL_S

Seite 52

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)22OPENHPI_VARPA

Seite 53

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)23OPENHPI_LOGFL

Seite 54 - 4.5 Artesyn Extensions

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)24OPENHPI_CRASH

Seite 55

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)25MaxOutstandin

Seite 56

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)26RmcpPrivLimit

Seite 57 - 4.5.3 POST Type Control

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)27Script<old

Seite 58 - 4.5.4 Shelf-Specific Mappings

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)282.3 Setting U

Seite 59 - 4.5.5 HPI Logging Support

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)293. If applica

Seite 60

ContentsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)3About this Manual . . . . . . . . . . . . .

Seite 61

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)30In the follow

Seite 62

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)31If you want t

Seite 63

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)322.3.2.2 Acces

Seite 64

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)33Once the prev

Seite 65

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)34Make sure tha

Seite 66

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)352.4.2 Configu

Seite 67

Software Installation and ConfigurationSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)36 # snmpwalk

Seite 68

Chapter 3System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)37Developing Applications3.1 OverviewThis cha

Seite 69

Developing ApplicationsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)38After extracting the RPM or C

Seite 70

Chapter 4System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)39Using HPI-B4.1 OverviewThis chapter provide

Seite 71 - 4.5.11 IPMI Command Control

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)Contents4ContentsContents4.3 Backward Compatibility .

Seite 72

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)40In case of OEM multi records, Artesyn HPI

Seite 73 - 4.5.12 Boot Bank Control

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)414.2.2 Limitations with Respect to HPI-B A

Seite 74

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)424.3 Backward CompatibilityThis section de

Seite 75

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)434.4 Working with the Multishelf LibraryTh

Seite 76

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)44Any FRUs available in a shelf are represe

Seite 77 - 4.6 Cooling Management

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)45In the Artesyn HPI-B implementation, the

Seite 78

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)46Figure 4-2 HPI Multishelf Library - Overv

Seite 79

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)47In the following, the Domain Management R

Seite 80

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)48The RDR and the HPI control are defined a

Seite 81

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)494.4.3.2 Shelf Management ResourceThe shel

Seite 82

ContentsSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)5A Example Applications . . . . . . . . . . .

Seite 83

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)50The shelf management resource contains th

Seite 84

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)514.4.3.3 HPI Domain EventsDepending on the

Seite 85

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)524.4.4 Discovering Shelves and DomainsAs p

Seite 86

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)53After calling saHpiControlStateSet(), a n

Seite 87

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)54If the domain/shelf specified in the call

Seite 88

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)55This control maps the IPMI commands Set S

Seite 89

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)56Example: On most Artesyn blades, the BIOS

Seite 90

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)574.5.3 POST Type ControlThis HPI control a

Seite 91

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)584.5.4 Shelf-Specific MappingsThe followin

Seite 92 - Instrument

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)594.5.5 HPI Logging SupportThe actions take

Seite 93

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)Contents6ContentsContents

Seite 94

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)60Table 4-19 Log Control State SaHpiCtrlSta

Seite 95

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)614.5.6 HPI Daemon Redundancy SensorThe Art

Seite 96

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)62IsFru SAPHI_FALSE Per the rules stated in

Seite 97

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)63RdrTypeUnion.SensorRec.DataFormat.Modifie

Seite 98

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)644.5.7 Active and Stand-By HPI Daemon Sens

Seite 99

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)65RdrTypeUnion.SensorRec.Num MOTHPI_SENSOR_

Seite 100 - Using HPI-B

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)66RdrTypeUnion.SensorRec.DataFormat.Reading

Seite 101

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)674.5.8 HPI Daemon Switchover ControlThis H

Seite 102

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)68Note that the initiation of a switchover

Seite 103 - Example Applications

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)694.5.9 Failed Slot Restore Control"Fa

Seite 104

List of TablesSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)7Table 1-1 HPI-B Standards Supported by

Seite 105

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)704.5.10 HPI Restart Daemon ControlHPI Rest

Seite 106

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)714.5.11 IPMI Command ControlIPMI command c

Seite 107

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)72Table 4-34 IPMI Command Control SaHpiCtr

Seite 108

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)734.5.12 Boot Bank ControlBoot Bank control

Seite 109

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)744.5.13 SOL Configuration ControlSOL confi

Seite 110

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)75Type SAHPI_CTRL_TYPE_OEMOutputType SAHPI_

Seite 111

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)76StateUnion.Oem.Body Parameters0(SetInProg

Seite 112

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)774.6 Cooling ManagementAs mentioned earlie

Seite 113

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)78If more than one sensor has reached the t

Seite 114

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)79Reboot the Shelf Manager or restart the H

Seite 115

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)8List of TablesTable 4-25 Active and Stand-By HPI Daem

Seite 116

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)80If the debug logs are enabled for the coo

Seite 117

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)81Following table describes the way to inte

Seite 118

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)824.6.2 External Cooling ManagementIf you d

Seite 119

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)83Synopsishpicooling [-h][-d domain_id] [-m

Seite 120

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)84Use domain domain_id.-s speedSet fan spee

Seite 121

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)85Entity Cooling resource entityIsFru Unuse

Seite 122

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)86As mentioned above, each domain furthermo

Seite 123

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)874.7 Serial Over LAN ConfigurationThe ATCA

Seite 124

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)88Example:Shelf IP address = 172.16.3.0l

Seite 125

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)89Sol_ForcePayloadEncryption 1: configures

Seite 126

List of FiguresSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)9Figure 1-1 Overview of HPI Usage in Sy

Seite 127 - A.4 hpi_shell Utility

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)90Sol_AddressOffset IP address offset Any v

Seite 128

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)91Sol_Config 0: Default IP address assignme

Seite 129

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)92The open source tool ipmitool can be used

Seite 130

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)93FUMI allows to programmatically update th

Seite 131

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)94Synopsishpifumi [-d DOMAIN_ID] [-r RESOUR

Seite 132

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)95Invokes the FUMI saHpiFumiUpgradeStart()

Seite 133 - Related Documentation

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)96This invokes the FUMI call saHpiFumiTarge

Seite 134

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)97-TTarget IPMC component information, comp

Seite 135

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)98ExampleUpdating the IPMC Firmware of HPM.

Seite 136

Using HPI-BSystem Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)99resource: 77 ATCA-9305: {ADVANCEDTCA_CHAS

Kommentare zu diesen Handbüchern

Keine Kommentare